Your Best Choice for Furnace and Air Conditioning Repair in Orem, UT

In the Salt Lake and Utah Counties, Western Heating & Air Conditioning is well known for providing exceptional repair, installation, and service. The people we send out to serve you are also top notch, something you'll see in their reviews below. Everyone you deal with at our company has the goal of making sure your experience with us will be so good you'll call us every time you need help. You can feel confident working with Western Heating & Air Conditioning because we stand behind our work and comply with all local codes. This is why, as you can see by the map and reviews below, we are rated so highly for Furnace and Air Conditioning Repair|Orem, UT| Western Heating & Air in Orem UT. Call us today at (801) 224-8899!

Local reviews for Furnace and Air Conditioning Repair in Orem, UT.

Local Reviews
for Orem, UT

Western Heating & Air Conditioning Rated 4.9 out of 5 stars based on 263 customer reviews

Map of Orem, UT

Great service




Review of Western Heating & Air Conditioning

Great service. Friendly, professional and relatable.


Response from Western Heating & Air Conditioning:

Hi Cameron, your 5 star review is very much appreciated. Thank you for having Wes out to your home today.


Map of Orem, UT

Great service




Review of Western Heating & Air Conditioning


Response from Western Heating & Air Conditioning:

Hi Marie, you are so kind to give Tracy a 5 star review! It has been our pleasure to be able to help with your home comfort.


Map of Orem, UT

Great service




Review of Western Heating & Air Conditioning

Very professionally done and nice workers


Map of Orem, UT

Very nice, no problem for me! So glad to have it done!




Review of Western Heating & Air Conditioning

I appreciate the service. You arrive promptly when you say you will!!


Map of Orem, UT

I had the most thorough, nice tech guy who came out promptly.




Review of Western Heating & Air Conditioning

I will use Western for any Heating A/C problems I may have.


Map of Orem, UT

We always turn to Western Heating and Air and have for many years. We love this company and their employees!




Review of Western Heating & Air Conditioning


Map of Orem, UT

Great Service




Review of Western Heating & Air Conditioning


Map of Orem, UT

Air duct cleaning




Review of Western Heating & Air Conditioning

They did a great job cleaning the air ducts in my house. They came on time they worked hard, they kept the noise to a minimum and cleaned up anything that they needed to.


Map of Orem, UT

Great Service




Review of Western Heating & Air Conditioning

Wesley seems to be a good worker**


Map of Orem, UT

Great Service




Review of Western Heating & Air Conditioning

Very friendly and efficient.


Efficient Work




Review of Western Heating & Air Conditioning

John's work was very professional. The overall service from Western Heating and Air Conditioning took time and office workers were a little confused about some of the work that was needed for the finishing up of the repairs for Carbon Monoxide leakage problem. Technicians who installed the combustion air pipes did a great job!


Great Service




Review of Western Heating & Air Conditioning


options




Review of Western Heating & Air Conditioning

Helpful in explaining options.


Great Service




Review of Western Heating & Air Conditioning


Great service




Review of Western Heating & Air Conditioning

Sure happy Western Heating & Air service is available 24/7. Late Friday after noon I discovered my AC was not cooling the house even though the outside compressor was still working and the output was freezing up at the unit, but the blower on the furnace was not. I called Western Heating and Air at 7:15 Saturday morning and requested a service man ASAP but preferable by noon. Late in the morning I received a call that it would be scheduled for 3:00 pm. To my surprise at 2:15 one of their excellent service men, Najee Banks arrived and determined the furnace heater motor had to be replaced. He did not have one on his truck,but did have one in their warehouse. When I told him I had a commitment later in the afternoon he said he could come back on Sunday and agreed to make it in the afternoon because I had church commitments in the morning. He returned as promised, installed a new motor and it sure made sleeping again possible Sunday night. I have been a happy customer of Western for over 10 years and still am.


Great service




Review of Western Heating & Air Conditioning

They were fast, courteous and professional. In whole it was a great experience.


Great service




Review of Western Heating & Air Conditioning

Very good experience


Great service.




Review of Western Heating & Air Conditioning

He did a great job and was very friendly!


Quick efficient courteous




Review of Western Heating & Air Conditioning


Response from Western Heating & Air Conditioning:

Thank you Doreen


Mark saves the day!




Review of Western Heating & Air Conditioning

We had some issues with our water heater exhaust pipe and Mark was amazing to work with. He not only fixed the problem but took the time to show and explain why it needed to be a certain way to bring it up to code. He was very patient, professional and understanding. If i ever have a problem again I am going to specifically request Mark be our service representitive.


Response from Western Heating & Air Conditioning:

You are absolutely right about Mark, he is so wonderful to have apart of our Western team and even better he get's to service such amazing client's just like you Kim!


Jeff M.

Jeff M.

AC tune up refer to health inspection report. Replaced filter with new filter these 4” filters need replacing between 4-6 months depending on usage, if upgrading to an Aprilaire it will be able to go to at least a year. Ambient temperature too cold for accurate readings on refrigerant pressures. There does not appear to be cause of concern with pressures given the temp split and refrigerant detector meter did not pick up any refrigerant leaks. Mild pitting and burning. Mostly burning from organic material making its way between contacts and burning when contacts come together. Equipment both inside and outside do not have any surge protection devices in use. Recommendations refer to estimates.

Near W 500 S St, Orem, UT 84058
Ben N.

Ben N.

The bryant furnace was not working. The fuse was broken. We replaced the fuse today. He just wanted to do the service call today. He did not want to do a tune up or replace the filter.

Near 40 W, Orem, UT 84058
Ryan H.

Ryan H.

Maintenance plan AC tuneup. Overall system looks good. Should be good for summer. No major concerns at this time.

Near W 175 N St, Orem, UT 84057
Kade C.

Kade C.

Performed ac tune up. Found a bad capacitor on the condenser. I replaced it today. The other tests were all normal. See health report card. Thank you for your business.

Near N 630 E St, Orem, UT 84097
Ryan H.

Ryan H.

Maintenance plan AC tuneup. Overall AC is in working condition. Most areas of the health report card are in green. AC dual run capacitor is reading a little low. Noticed the water heater is 11 years old. Recommend replacing it before it begins to leak. Included prices for: AC tune up kit that includes all new start and run components capacitor, contactor and hard start kit. This is the best bang for the buck verses doing them separately. Wet switch to install in basement to alert if any flooding takes place from the water heater A bundle price to do both together. Price for replacing 50 gal water heater with new expansion tank per code. Price to flush and clean water heater burners to hopefully extend its life.

Near S 900 E St, Orem, UT 84097
Ryan H.

Ryan H.

Complementary AC tuneup. Performed full detailed AC tuneup. All mechanical, electrical and safety components are reading in manufacturers specs.

Near W 1455 N, Orem, UT 84057
Kade C.

Kade C.

System down due to an oxidized flame sensor. I tested gas pressure and found it low at only 2in in high stage 1.1in in low. O2 in the combustion gas was high at 16%. I replaced flame sensor under warranty and adjusted the gas pressure up to 3.2in on high and 2.2 on low per manufacture specs. CO in exhaust was within range at 30ppm. O2 in range at 8%. Unit is up and running upon departure.

Near N 760 W, Orem, UT 84057
Ben N.

Ben N.

Prepaid msc tune up on a 2016 amana ac. The contactor has lots of pitting. The blower wheel is dirty. Today I did a 29 point furnace tune up. We cleaned the blower wheel. The furnace was running when we left.

Near N 550 W St, Orem, UT 84057
Wesley D.

Wesley D.

Pvc drain was leaking out of elbow. Repaired drain. Drain is not leaking anymore.

Near N 85 E St, Orem, UT 84057
Ben N.

Ben N.

We came to do a prepaid ac tune up on a 2001 ac. The contactor is pitted. They have not added ac renew. Today we did a 29 point ac tune up and changed the contactor. They did not want to do anything else today. The ac was running when we left.

Near E Quail Rd, Orem, UT 84097
Spencer D.

Spencer D.

Complete furnace tune up. Inducer motor may need to be replaced.

Near N 1060 W, Orem, UT 84057
Tracy F.

Tracy F.

Came out for no heat found flame sensor was testing at .03 I cleaned sensor and now it reading at a 2. This is testing proper. I do recommend replacing flame sensor because of age. Filter is clean but is a merv 11. This is more restrictive on duct. We should be putting a merv 8 in. Temp split was proper at 51 degree difference. I did not perform a tune up today had one done not to long ago by Ben. All other parts are working properly at this time. Air flow is proper. Furnace was working properly when I left the call.

Near 400 S, Orem, UT 84058
Kade C.

Kade C.

Found 2016 Aire Flo (Lennox) Furnace down today due to a pressure switch that would not close. When closing the switch manually switch did not Ohm out to 0. Meaning that the pressure switch had failed. Installed new pressure switch, and cleared some debris out of the inducer housing. System is up and running upon departure.

Near S 70 W St, Orem, UT 84058
Kade C.

Kade C.

Call warranty no heat. Found the unit in a fault 13 indicating high limit fault lock out. Turned unit off and back on to reset fault. Let unit run and tested air flow and temperatures and found there to be no issues with those. While unit ran the primary high limit tripped and fault 33 code flashed. None of the manual roll out switches had tripped the auto reset was the only high limit to fault. Turned unit off and back on to reset and tested the switch the voltage was spiking up and down on the one side of the switch indicating the contacts for the switch opening and closing. Jumped the switch and let system run while testing ohming across switch contact. While switch manually jumped system did not shut off, while ohming switch out the switch was jumping sporadically from 0-0.5 ohms pointing towards contacts moving in an abnormal fashion. Within about 10 mins in high stage the high limit switch tripped prematurely and supply temp was at 126.1 degrees not hot enough to cause switch t

Near E 40 N St, Orem, UT 84097
Kade C.

Kade C.

Quarterly maintenance and filter change out. I noticed the power disconnect on the unit does not work properly and as to me manually closed with a screw driver. This is a safety concern and needs to be replaced. All other components are working as they should. I have included an estimate for the replacement of the component.

Near N State St, Orem, UT 84057
Jason B.

Jason B.

Fixed nouse in furnace

Near W 650 S, Orem, UT 84058
Ryan H.

Ryan H.

Furnace was only blowing cold air. Customer did a repair and then it wouldn’t do anything at all. Performed full detail furnace tuneup. Found that the fuse had been blown, probably during the repair. Upon completing the health report card all areas were in the green except for the blower capacitor. Replaced the blower capacitor. Furnace is 18 years old. Customer will be replacing the furnace and water heaters in the future. Asked about tankless water heaters. Customer had some concerns about the venting but with the tankless and a 90% furnace there shouldn’t be a problem.

Near 720 N, Orem, UT 84097
Jeff M.

Jeff M.

Call no heat. Found unit indicating a fault 4 code high limit switch open. Checked all switches and found the auto reset limit switch to be open and would not close. Replaced and then transformer blew. Checked for fuse and there is no fuse to protect the equipment from over amps or dead shorts. Transformer needs to be replaced to establish power to control board, hopefully no harm has come to control board physically there does not appear to be any damage to it a new transformer will be the real and only way to establish its integrity. Transformer replaced and system was able to run appropriately. With new transformer wired in a 3 amp fuse to help mitigate the potential of transformers blowing out due to shorts. Water heater has drafting issues it’s showing signs of combustion byproducts exiting the burner compartment of the water heater. Water heater is off and should remain off until replaced this is a safety concern.

Near S Columbia Ln, Orem, UT 84097
Jordan R.

Jordan R.

Inducer #122 blower motor is 1/3. Both need to be replaced on the basement furnace. I have replaced the capacitor on the basement furnace and both air filters on the furnaces. I have scheduled an appointment for 2pm on Saturday 2/27/21 to come back and replace the inducer and blower motor. Payment has been made in full

Near E 1220 N, Orem, UT 84097
Hunter B.

Hunter B.

Upon arrival system was operating, customer woke up to home being 66 degrees, the furnace had a fault code 33 rollout limit. I manually reset the rollout switch and furnace code was normal operation. Furnace is a direct vent outside with 1 elbow, total length of 12 feet. After watching furnace run and checking history codes I believe wind blew the flame back carouse the rollout to trip. Discussed issue with customer and explained if it happens again we might need to change the rollout switches due to bad sensor.

Near E 40 N St, Orem, UT 84097
Gabriel B.

Gabriel B.

I performed a furnace tune up on a 2002 Trane system. The system is showing signs of age but it is working properly. See health report card.

Near E 2000 S St, Orem, UT 84058
Gabriel B.

Gabriel B.

I performed a furnace tune up on two 2018 Amana systems. The Basement system is working but it has a bad high stage pressure switch. This switch should be under warranty, the office will call to schedule a time to come and replace it. Other than that the system is working safely and properly. I changed the filter. The Upstairs system is working but it has a high static pressure. This means the system is working really hard to move air. This causes the system to overheat and shut down as a safety precaution. I adjusted the gas pressure from 3.85inWC to 2.77inWC for a better combustion and better temperature. I changed the filter. The system was working safely and properly when I left. See health report card.

Near N Palisades Dr, Orem, UT 84097
Jason B.

Jason B.

Furnace and airconditioning replacement 80% $99.00 monthly

Near W 650 S, Orem, UT 84058
Ryan H.

Ryan H.

MSC tuneup. Overall furnace is in good condition. Nothing out of specs. Filter is dirty. Recommend replacing it every 4 month due to high merv rating. Found refrigerant leak in evap coil. Included price to replace it. Also included prices for indoor air quality products to help with dust and allergies. Sending comfort supervisor to talk about possible replacement options.

Near 50 W, Orem, UT 84057
Ryan H.

Ryan H.

Call for no hot water. Water heater pilot had gone out. Tried lighting it several times with no success. Opened the sealed combustion chamber and allowed air to enter and it lit right up. Found the metal grate covering the bottom was plugged up preventing clean air to enter and burn. Pulled burner and cleaned the burner and the screen removing the debris and dirt. Flushed out water heater to remove as much hard water build up as possible. Water heater is 14 years old. Average life is 10-12. Included price to replace water heater. It is impossible to know exactly how long a water heater will last. Recommend keeping an eye on it and watch for leaks. Customer signed up on maintenance program. Performed furnace tune up today. Furnace is also 14 years old. Overall in working condition. Some heat spots starting to form on the heat exchanger as is normal for this age of furnace. Customer will replace the filter. Customer mentioned her AC died last summer. When spring comes she would l

Near N 240 E, Orem, UT 84057
$
 
Contact Information
 
235 Mountainlands Dr.  •  Orem, UT 84058